STC ratings explained for hotel and residential refurbishment
What an STC number does and does not tell you, why the lab figure is not what the guest hears, and how to set a realistic target.
What STC measures
Sound Transmission Class is a single-number rating derived from transmission loss measured across standard frequency bands, per ASTM E90 in the laboratory. It compresses a curve into one figure so that products and assemblies can be compared quickly.
That compression is also its weakness. Two assemblies with the same STC can behave very differently — particularly at low frequencies, which the rating weights lightly.
Lab rating versus field performance
A laboratory figure is measured on a carefully built assembly with no flanking. On site you have service penetrations, door undercuts, continuous ceiling voids and workmanship variation. The field result is routinely several points below the lab number.
Set expectations accordingly. If a client needs a genuine field result, specify to a field-measured target and allow margin against the lab figure.
Why guests still complain at a good STC
STC is weighted towards speech frequencies. A guest kept awake by a bass line from the bar downstairs, by a chiller, or by footfall is hearing energy below the range STC treats seriously.
For those complaints, look at the low-frequency behaviour of the assembly rather than the headline number — and consider a barrier formulation tuned for low frequency.
Setting a target that survives handover
Decide what the space has to achieve in service, not on paper: sleep in a bedroom, confidentiality in a consulting room, no bleed between cinema screens. Then work back to an assembly with margin, and budget for sealing and detailing rather than only for the barrier material.
Products referenced
BB830 — The flagship acoustic optimized MLV barrier for walls, ceilings and floors where added mass has to fit in a shallow build-up. Aluminium faced, with the facing to the noise source, where it also acts as a vapour barrier.
BB830FR — The BB830 barrier in a fire-retardant formulation, for projects where the acoustic layer has to satisfy fire requirements as well as an STC target — with no loss of acoustic performance.
BB830LF — The heavy low-frequency sheet, tuned for bass energy — plant rooms, studios, cinemas and any partition where low-frequency transmission rather than speech is the complaint.
BB850 — Acoustic lagging for pipes and ductwork: a 5 kg/m² limp mass barrier over a hydrolysis-resistant polyether foam decoupling layer, foil faced. For noise break-out from PVC soil stacks, waste and hydraulic pipework and sheet-metal duct. Figures below are the manufacturer's declared data; the test report is available on request.
BB860 — A composite acoustic lining: a 6 kg/m² mass loaded vinyl barrier bonded between two 25 mm layers of polyether polyurethane foam. Barrier and absorber in one lining, for acoustic enclosures, generator and compressor housings and plant room linings. No acoustic test report is published for this composite yet, so no performance figures are quoted.
BB460 — Self-adhesive damping sheet that stops metal panels ringing. Peel, press, done: 2 mm butyl with an aluminium face, 3.86 kg/m², for ducts, hoppers, machine guards and vehicle panels. Damps the panel it is stuck to; it is not an MLV barrier, so pair it with BB830 or BB830LF where airborne sound must be blocked.
Supply in Southeast Asia
BlastBlock supplies the full range across
Thailand, Malaysia, Indonesia, Vietnam, Philippines, Singapore. Distribution enquiries:
info@blast-block.com.